4. Signal Conditioning
Basically, all sensors out there will translate the physical information they have to sense in the electrical
domain, by conveniently changing an electrical quantity (output signal) that is either a:
• Voltage
• Current
• Impedance (or related quantity, e.g., capacitance or inductance)
Measuring these quantities needs appropriate circuitry (that will depend on the quantity typology and on the
specifications of the sensor output).
Once the information about a physical process is acquired by a sensor and encoded in its output, it is
necessary to perform some actions. Specifically, the sensor output, that is either a voltage, a current, or an
impedance, needs to be measured by specific circuitry. Then, the signal must be manipulated appropriately
to make it suitable for further computation. Specifically, in most cases the signal at the output of the sensor
is feeble (small in amplitude) and may contain some information which is not really needed (for instance,
some frequency components that we may want to attenuate or eliminate). Typically, most of the
computation is performed digitally, for many reasons that were already discussed in the first chapter (e.g.,
economic advantage, noise robustness, re-programmability, re-configurability, and so on). Therefore, the
signals acquired from sensors are analog, and thus need to be converted in digital format by appropriate
circuits, known as analog to digital converters (ADCs). However, such circuits have specific requirements for
the analog signals at their input. For instance, if the analog signal at the input of an ADC is too feeble (small
in amplitude), the conversion process to the digital domain will not be successful. Also, it is desirable to
remove noise components and unwanted information as much as possible before analog to digital
conversion. Therefore, in between sensors and ADCs we typically find some analog circuitry that performs
specific actions, typically acquisition of the sensor output, amplification, and filtering. In the following, we
will have a look at circuit arrangements for measuring impedances (bridge circuits), for amplification of
current and voltage signals, and for filtering.
4.1. Bridges
Bridges are circuits in which (at least) two circuit branches (typically in parallel) are "bridged" by a third
transverse branch connecting the parallel branches. Originally developed for laboratory measurement
purposes, they find nowadays many applications:
• Sensing: namely, it can be used to sense the value of unknown passive elements (excellent for sensor
readout) like resistive, inductive, and capacitive elements.
• Filtering
• Power conversion
• Instrumentation
4.1.1. Wheatstone bridge
The simplest bridge circuit is the so-called Wheatstone bridge. It is composed by two parallel branches (A-D-
C and A-B-C in the following figure), bridge by a transverse branch (B-D). In each of the two parallel branches
there are two resistors, while a measurement device (typically a voltmeter or a galvanometer) is present on
the transverse branch. Specifically, in one of the parallel branches there is a fixed resistor of known value (R
1
65
in the following figure), and a variable resistor (a potentiometer, R
2
) that value of which can be varied. In the
other parallel branch there is a resistor of fixed value (R
3
), and the resistor of unknown value that is to be
measured (R
x
). The whole structure is biased by a constant voltage source connected between nodes A and
C.
The working principle of this circuit is based on reaching the so-called null condition by adjusting the value of
R
2
which is:



In this condition, no current flows into the transversal branch and:
Typically, the device in the transverse branch is a galvanometer, that can detect very small currents with
extremely high precision. If R
2
is changed until the galvanometer detects zero current, then the effect of any
parasitic current will be negligible and error on the evaluation of R
x
will be also negligible. If R
1,2,3
are known
to high precision then R
x
will be known to high precision. Usually, common cheap resistors have a tolerance
of ± 5 %. However, for this bridge circuit, resistors with a much smaller tolerance (that are much more
expensive) are recommended to minimize errors. If R
1,2,3
are known but R
2
is not adjustable, V
G
(or I
G
) is used
to sense R
x
using KVL and KCL.
In the case of R
x
being very small, then the cables’ and terminals’ resistances are no more negligible, and this
circuit typology becomes ineffective for sensing R
x
. Indeed, to sense very small resistances (typically below 1
Ω) the Kelvin bridge is used.
4.1.2. Kelvin bridge
If a small resistance is to be measured, the Kelvin bridge can be used. The problem, in this case, is that the
parasitic resistance of the connecting wires is comparable to the one that we want to measure, which makes
the Wheatstone bridge ineffective. The Kelvin bridge arrangement is akin to the one of Wheatstone bridge,
but more resistors are used. Moreover, some of these resistors will be four-terminals resistors (sketched on
the right panel of the figure below, see also the discussion on Shunt current sensor in chapter 3).
Vj
=
V
-
Vo
dove
epuledrio
V
=
r
Ry
+
Rx
No
?
Non
fatto
a
lezione

Visualizza gratis il Pdf completo

Registrati per accedere all’intero documento e trasformarlo con l’AI.

Anteprima

Condizionamento del segnale

4. Signal Conditioning Basically, all sensors out there will translate the physical information they have to sense in the electrical domain, by conveniently changing an electrical quantity (output signal) that is either a:

  • Voltage
  • Current
  • Impedance (or related quantity, e.g., capacitance or inductance)

Measuring these quantities needs appropriate circuitry (that will depend on the quantity typology and on the specifications of the sensor output). Once the information about a physical process is acquired by a sensor and encoded in its output, it is necessary to perform some actions. Specifically, the sensor output, that is either a voltage, a current, or an impedance, needs to be measured by specific circuitry. Then, the signal must be manipulated appropriately to make it suitable for further computation. Specifically, in most cases the signal at the output of the sensor is feeble (small in amplitude) and may contain some information which is not really needed (for instance, some frequency components that we may want to attenuate or eliminate). Typically, most of the computation is performed digitally, for many reasons that were already discussed in the first chapter (e.g., economic advantage, noise robustness, re-programmability, re-configurability, and so on). Therefore, the signals acquired from sensors are analog, and thus need to be converted in digital format by appropriate circuits, known as analog to digital converters (ADCs). However, such circuits have specific requirements for the analog signals at their input. For instance, if the analog signal at the input of an ADC is too feeble (small in amplitude), the conversion process to the digital domain will not be successful. Also, it is desirable to remove noise components and unwanted information as much as possible before analog to digital conversion. Therefore, in between sensors and ADCs we typically find some analog circuitry that performs specific actions, typically acquisition of the sensor output, amplification, and filtering. In the following, we will have a look at circuit arrangements for measuring impedances (bridge circuits), for amplification of current and voltage signals, and for filtering.

Ponti di misura

4.1. Bridges Bridges are circuits in which (at least) two circuit branches (typically in parallel) are "bridged" by a third transverse branch connecting the parallel branches. Originally developed for laboratory measurement purposes, they find nowadays many applications:

  • Sensing: namely, it can be used to sense the value of unknown passive elements (excellent for sensor readout) like resistive, inductive, and capacitive elements.
  • Filtering
  • Power conversion
  • Instrumentation

Ponte di Wheatstone

4.1.1. Wheatstone bridge The simplest bridge circuit is the so-called Wheatstone bridge. It is composed by two parallel branches (A-D- Cand A-B-C in the following figure), bridge by a transverse branch (B-D). In each of the two parallel branches there are two resistors, while a measurement device (typically a voltmeter or a galvanometer) is present on the transverse branch. Specifically, in one of the parallel branches there is a fixed resistor of known value (R) 64in the following figure), and a variable resistor (a potentiometer, R2) that value of which can be varied. In the other parallel branch there is a resistor of fixed value (R3), and the resistor of unknown value that is to be measured (Rx). The whole structure is biased by a constant voltage source connected between nodes A and C. A R1 R3 + D VG B R R x C VG = VO - VB dove x equilibrio : VD =V R1+R2 Ve = V - Rx R3 + Rx The working principle of this circuit is based on reaching the so-called null condition by adjusting the value of R2 which is: we adjust R2 so that VG = 0 In this condition, no current flows into the transversal branch and: R2 R1 Rx =R → R3 Rx = R3 · R2 RT Typically, the device in the transverse branch is a galvanometer, that can detect very small currents with extremely high precision. If R2 is changed until the galvanometer detects zero current, then the effect of any parasitic current will be negligible and error on the evaluation of Rx will be also negligible. If R1,2,3 are known to high precision then Rx will be known to high precision. Usually, common cheap resistors have a tolerance of + 5 %. However, for this bridge circuit, resistors with a much smaller tolerance (that are much more expensive) are recommended to minimize errors. If R1,2,3 are known but R2 is not adjustable, VG (or IG) is used to sense Rx using KVL and KCL. In the case of Rx being very small, then the cables' and terminals' resistances are no more negligible, and this circuit typology becomes ineffective for sensing Ry. Indeed, to sense very small resistances (typically below 1 Q2) the Kelvin bridge is used.

Ponte di Kelvin

4.1.2. Kelvin bridge NO? Non fatto a lezione If a small resistance is to be measured, the Kelvin bridge can be used. The problem, in this case, is that the parasitic resistance of the connecting wires is comparable to the one that we want to measure, which makes the Wheatstone bridge ineffective. The Kelvin bridge arrangement is akin to the one of Wheatstone bridge, but more resistors are used. Moreover, some of these resistors will be four-terminals resistors (sketched on the right panel of the figure below, see also the discussion on Shunt current sensor in chapter 3). R of connecting wires R of resistor Current Pins R - M -m Voltage Pins 65In the Kelvin bridge circuit, the aim is to eliminate the contribution of the parasitic resistance of the unknown resistance and of the variable resistor on the same branch by using four-terminal resistors (Ra, variable and known, Rx unknown). In addition, some two-terminal resistors are used (Rm, Rn, RM, RN). By looking at the sketch below, it is easy to see that, compared to the Wheatstone bridge, the Kelvin bridge is effectively supplied by the voltage that falls across the upper voltage terminal of Ra and the lower voltage terminal of Rx, physically cutting out of the circuit the voltage drops on two of the four parasitic wire resistances (Rwire). Specifically, the parasitic resistances between i) the upper current and voltage pins of Ra, and between ii) the lower current and voltage pins of Rx are physically excluded. However, the voltage drops between iii) the lower current and voltage pins of Ra and iv) the upper current and voltage pins of Rx are not physically cut out of the bridge. Ewire Ra Ra RM N Ewire W Pm null null R. E -wire N RN R Rx Ewire However, if the null condition is reached by varying Ra, then by applying KVL and KCL one obtains the following equation: Rx - RN + Rwire Ra RM ⋅ Ra Rm + Rn + Rwire Rm ⋅ RN RM Rn ) Rm − It is easy to notice that the above equation is the same as the one derived for the Wheatstone bridge except for an additional term that depends on Rwire and that is introduced by the presence of the two parasitic resistances (out of four total parasitic resistances) that are not physically cut out. However, this additional term can be forced to be exceedingly small by appropriately setting the value of the two-terminal resistors. Indeed: if RN - Rn RM Rm Rx = = RM RN · Ra Also for the Kelvin bridge, care must be taken to choose two-terminal resistors with low tolerance to minimize errors in the estimation of the unknown resistance.

Ponte di Maxwell

4.1.3. Maxwell bridge The concept of the Wheatstone bridge can be generalized to measure an unknown impedance. The resulting circuit is called Maxwell bridge (the two are compared in the following figure). The structure is identical to the one of the Wheatstone bridge but i) an AC voltage source is used instead of a DC one; ii) the resistor R1 is replaced by a more general impedance Zi, in this case the parallel of a resistor and a capacitor iii) the unknown resistance Rx is substituted with an unknown impedance Zx = Rx + jXx. (where Rx is the resistance and Xx the reactance of the unknown impedance). It is important that the two impedances that are not purely resistive are chosen to have reactance values of opposite signs. In the following figure, an example where the unknown impedance has positive reactance is proposed, but the discussion holds true also for a negative unknown reactance. In the latter case, the known impedance should have positive reactance. 66 M N RN RMA R N R2 R 1 R3 C + + D V B 1 L R R N R x R C Specifically, if we are able to vary the frequency (@) of the AC voltage source, then at a particular frequency we will have the null condition and (no matter how the unknown impedance is made): Z1 · Zx = Z2 · Z3 This equation involves complex numbers (Z) and Zx), and as such can be divided in two real equations by equating separately the real and imaginary parts of the two members: R(Zx) = R Š(Zx) = 3 Z2 . Z3 Z1 Z2 . Z3 Z1 The solution of the first equation will give as a result Rx and the second one X .. Of course the value of wto be used in the above equations is the one for which the null condition is obtained. However, it is also possible to reach the null condition if the @ of the AC source that we use cannot be controlled. In this case, we can use a variable capacitor and adjust its capacitance to reach the null condition. However, the first solution is preferred because it involves fixed components (typically much more accurate and less prone to introduce errors). Moreover, the w of state-of-the-art AC voltage source can be controlled with high accuracy. Another point to notice is that, since reactive components do not react to DC signals, at w = 0 the capacitor is an open circuit while the inductor is a short circuit. If we use a DC source, we get back the Wheatstone bridge topology. This approach can be used to have an independent estimation of the real part of the unknown impedance.

Operazioni tipiche

4.2. Typical Operations Signal conditioning means manipulating an analog signal in such a way that it meets the requirements of the next stage for further processing (typically an A/D converter, ADC). It includes amplification, filtering, converting, range matching, isolation and any other processes required to make sensor output suitable for subsequent processing.

Filtraggio del segnale

Filtering Usually not all the signal frequency spectrum contains important data, so we might want to filter out some components (for instance, the 50/60 Hz AC power lines, present in most environments, which cause unwanted noise if amplified).

Amplificazione del segnale

Amplification Signal amplification performs two important functions: increases the resolution of the input signal and increases its SNR (signal to noise ratio), i.e. it boosts signal amplitude preserving its shape (with the lowest 67